Ductile Iron Pipe Icon
Fabricated Items

Thrust Collars

One method of restraining a pipeline is to provide a welded-on thrust collar or other dependable anchorage means on one or both sides of the point requiring restraint and to use concrete poured around the collar for support against undisturbed soil surrounding the pipe.

At a bend, the fitting and pipe ends would have to be of a restrained type, adequate to withstand total thrust involved. The required number of thrust collars would be dependent on the magnitude of the thrust force to be restrained and the allowable load per collar.

Thrust collars are also used in lieu of water stops on fabricated wall pipe for installation in load-bearing walls to resist thrust caused by internal pressure.

Read More
contact sales

Laying Lengths

Size
(in.)

Minimum Dimensions in inches

Flg-T/C-Flg

Flg-T/C-PE

PE-T/C-PE

MJ-T/C-MJ (Fab1)

MJ-T/C-PE

MJ-T/C-Flg

Fst-T/C-PE

Fst-T/C-Flg

O.A./L.L.

O.A./L.L.

O.A./L.L.

O.A.

L.L.

O.A.

L.L.

O.A.

L.L.

O.A.

L.L.1

O.A.

L.L.1

4

8

8

8

10

4 5/8

8

5 1/2

8

5 1/2

8

4 11/16

8

4 5/8

6

8

8

8

10

4 5/8

8

5 1/2

8

5 1/2

8

4 5/8

8

4 5/8

8

8

8

8

10

4 5/8

8

5 1/2

8

5 1/2

4 1/4

8

4 1/4

4 1/4

10

8

8

8

10

4 5/8

8

5 1/2

10

7 1/2

8

4 1/4

7 1/4

3 1/2

12

8

8

8

10

4 5/8

8

5 1/2

10

7 1/2

8

4 1/4

7 1/4

3 1/2

14

8 1/2

8

8

12

4 1/2

8

4 1/2

11

7 1/2

8

2 3/4

9 3/4

4 1/2

16

8 1/2

8

8

12

4 1/2

8

4 1/2

11 1/2

8

8

2 3/4

9 3/4

4 1/2

18

8 1/2

8

8

12

4 1/2

8

4 1/2

12

8 1/2

8

1 1/2

10

4 1/2

20

8 1/2

8

8

12

4 1/2

8

4 1/2

12

8 1/2

8

1 1/2

10

4 1/2

24

9 1/2

8

8

12

4 1/2

8

4 1/2

12

8 1/2

8

1 1/2

10

4 1/2

30

12

10 1/2

8

-

-

-

-

-

-

8

1 1/2

12

5 1/2

36

14

11 1/2

8

-

-

-

-

-

-

8

1 1/2

12

5 1/2

42

16

12

8

-

-

-

-

-

-

8 1/2

1

14

6 1/2

48

16

12

8

-

-

-

-

-

-

9

1

15

7

54

18

16

8

-

-

-

-

-

-

9 1/2

1

16

7 1/2

60

18

16

8

-

-

-

-

-

-

9 3/4

1

16

7 1/4

64

18

16

8

-

-

-

-

-

-

10

1

16

7

1.) Thrust collars may not be located in exact center of all minimum length pieces shown above.

2.) Laying lengths are rounded to the nearest 1/4".

Flange–Thrust Collar–Flange and Flange–Thrust Collar–PE pipe may be furnished up to 20’-0" length (with the exception of 4" whose maximum length is 17’-6"). Contact AMERICAN if longer lengths required.

Product Line Information

Domestic Certification
Submittals
Pipe Manual
Project Mgt/Customer Service
Standards
Aerial view of iron pipes

Contact Sales

Reach out to our sales team for more product information.
contact sales

Today's Infrastructure Solutions in the U.S. and Around the Globe.

About Us
American Mark