Ductile Iron Pipe Icon

Centrifugally cast wall pipe is manufactured for use in piping water through walls in water treatment plants and pump stations.

All AMERICAN fabricated wall pipe uses ductile iron components in combination with the following: cast or threaded on mechanical joint bells (can be tapped for studs), flanges (can be tapped for studs) and welded-on collars.

Wall pipe is normally fabricated of special thickness class 53 ductile iron pipe, but it may be furnished with minimum classes unless threaded flanges or threaded mechanical joint bells are included or unless specified otherwise.

Wall pipes with centrifugally cast mechanical joint bells will be provided instead with heavy-duty steel key locking thread inserts to accept threaded studs.

Flanges and mechanical joint bells of minimum-length pieces should normally be specified by the purchaser as “tapped for studs” to enable assembly of joints flush with the wall face.

Minimum-length pipes with plain ends in many cases do not allow enough room between the plain end and the collar to assemble joints. Consult AMERICAN for plain end joint assembly needs, which normally require longer pipes.

Read More
contact sales

Standard Dimensions

Plain End Pipe

Ductile Iron Centrifugally Cast

Size
(in.)

T lbs
Thickness
in.

Weight
lb/ft

T lbs
Thickness
in.

Weight
(lb/ft)

4

0.25

10.9

0.32

13.8

6

0.25

16.0

0.34

21.4

8

0.25

21.1

0.36

30.1

10

0.26

27.1

0.38

39.2

12

0.28

34.8

0.40

49.2

14

0.28

40.4

0.42

60.1

16

0.3

49.3

0.43

70.1

18

0.31

57.2

0.44

80.6

20

0.33

67.5

0.45

91.5

24

0.33

80.8

0.47

114.4

30

0.34

103.5

0.51

154.4

36

0.38

138.5

0.58

210.3

42

0.41

173.8

0.65

274.0

48

0.46

222.6

0.72

346.6

54

0.51

279.7

0.81

441.9

60

0.54

317.0

0.83

485.0

64

0.56

350.5

0.87

542.0

AWWA C151 – minimum thickness classes in this standard are Class 350 for 4”–12” sizes, Class 250 for 14”-20” sizes, Class 200 for 24” and Class 150 for 30”–64” sizes.

AWWA C115 – minimum thicknesses for all sizes of ductile iron pipe for threading on flanges.

Wall pipe is normally fabricated of Special Class 53 thickness ductile iron pipe but may be furnished with minimum classes unless threaded flanges or threaded MJ bells are included or unless specified otherwise.

Product Line Information

Domestic Certification
Submittals
Pipe Manual
Project Mgt/Customer Service
Standards
Aerial view of iron pipes

Contact Sales

Reach out to our sales team for more product information.
contact sales

Today's Infrastructure Solutions in the U.S. and Around the Globe.

About Us
American Mark